Part 2: Ethernet-Equipped RabbitCore
Modules
by Fred Eady
Start ý The
Networking Core ý Code Names and Comedy
ý Where and Why ý Completing
Initialization Down to Business
ý Now What? ý Sources
and PDF
DOWN TO BUSINESS
The first order of business is to make
sure youýre pointed at port D, which is mimicking the ý9346 data.
After thatýs done using the predefined EEPORT variable, the
first thing a real ý9346 wants to see is a start bit transmitted by
the RTL8019AS in Auto-Load mode. Because the RTL8019AS wants to read
the ý9346, a 2-bit Read opcode (10) is clocked out of the RTL8019AS
EEPROM pins. The next thing the ý9346 expects is 6 bits of address
information. The RCM2100 microprocessor doesnýt care about the address,
so the code just counts the address clock pulses and goes on to the
next task.
And that task is sending data to the
RTL8019AS that would normally come from a real ý9346 configuration
EEPROM. The ý9346 responds to a Read command by clocking out
the 16 bits of data at the requested address preceded by a zero bit.
Because youýre really not storing any vital data in your virtual ý9346,
the routine sends the 16-bit sequence 0x3030 one time. The iteration
count is controlled by the value of register C. The ý9346 emulation
routine then just sits and waits long enough for the ý9346 read to
complete and sets the EEDO line level to zero.
Knowing what was and wasnýt transferred
from the ý9346, looking ahead in the code tells you that you will
need an Ethernet or MAC address to continue with the initialization
process. These hardware addresses, or organizationally unique identifiers
(OUIs), are administered by the IEEE. The MAC address is a 6-byte
identifier with the first three bytes containing an IEEE-assigned
manufacturer code. The last three bytes are the unique station ID
assigned by the manufacturer. An array called EthAddress1 is loaded
with the RCM2100ýs preassigned MAC address. Although technically the
I/O base address of the RTL8019AS is 0x300 from its perspective, the
I/O base from the RCM2100ýs microprocessorýs perspective is the value
of PD_WR1, which you know is 0xC000. So, a call to the rt_init
function with the MAC address and microprocessorýs I/O base value
will help finish the process.
Listing
6 begins the final phase of
the RTL8019AS hardware initialization by loading the index register
IX with the base I/O address, youýll need to finish loading data into
the RTL8019AS internal configuration registers. After a jump to page
one, the RTL8019AS is stopped and the 6-byte MAC address is written
to physical address registers PAR#0ý5.
Just in case this isnýt the first time
this function has been called and there is activity on the Ethernet,
the RTL8019AS is halted. The 1.6-ms wait is long enough to allow any
transmit or receive activity to complete before continuing. The RTL8019ASýs
data configuration register is loaded with 0x58, which essentially
puts the NIC in a normal state. The DMA byte count registers are cleared
and the DMA start address is positioned at the beginning of the on-chip
SRAM at 0x4000. Normally, this chunck of memory would be carved out
of an external SRAM. In either place, itýs officially called the buffer
ring. The buffer ring is a contiguous set of fixed-length 256-byte
buffers. The RTL8019AS is put into Monitor mode and placed in loop-back
to avoid putting anything that falls into the 8-byte FIFO into the
buffer ring memory.
The receive buffer ring is delimited
by the values in PD_PAGESTART and PD_PAGESTOP. The DMA function
sees this buffer area as a logical ring. So, when the DMA address
reaches the Page Stop (PSTOP) address, the DMA address is reset to
the Page Start (PSTART) address. The static PSTART and PSTOP registers
are used in conjunction with two volatile registers, Current Page
(CURR) and Boundary Pointer.
Because each buffer area in the receive
buffer ring is on a 256-byte boundary, values placed in the Page Start
and Boundary (BNRY) registers must be multiplied by 256. So, the receive
buffer area begins at 0x4600 as 0x46 is loaded into the Page Start
register of the RTL8019AS.
The Boundary Pointer register is used
to point to a packet in the receive buffer ring that has not been
picked up by the RCM2100 microprocessor. Because you are in a Reset
mode, the Boundary Pointer is set to match the Page Start location
of 0x4600. In normal operation, each time a packet is removed from
the ring for processing, the Boundary Pointer is incremented. The
end of the receive ring buffer is defined in Listing 1 as 0x60 in
the PD_PAGESTOP definition. This Page Stop register value sets the
optimal receive buffer ring size for 8-bit operations. Even though
the Realtek has 16 Kb of memory, only 8 Kb is accessible when using
the 8-bit interface. If you could access the full 16-Kb range, the
top of the receive ring would be 0x8000 instead of 0x6000.
After clearing the interrupt flags, the
Transmit Page Start register (PD_TXPAGE) points back to the beginning
of the RTL8019AS SRAM. Your receive buffer starts a bit more than
one full Ethernet packet (0x600 bytes) from the beginning of SRAM
and the beginning of the transmit buffer. Before you turn the RTL8019AS
loose, it would be a good idea to point to the beginning of the receive
ring buffer so the first incoming packet wonýt flow into the transmit
buffer at the beginning of SRAM. After this is done, the code exits
Monitor mode and Loop-back mode, sets up to listen to the ether, and
clears any interrupt flags that may have popped up. If the RCM2100
is attached to an active Ethernet network, the activity and link LEDs
illuminate and the Ethernet hardware is on the air.
PREVIOUS
NEXT
Circuit Cellar provides up-to-date information for engineers. Visit
www.circuitcellar.com for
more information and additional articles.
For subscription information, call (860) 875-2199, subscribe@circuitcellar.com
or subscribe online.
ýCircuit Cellar, the Magazine for Computer Applications. Posted with
permission. |