Part 2: Hardware and Software Implementation
by Thomas Richter
Start ý The
Buck Converter ý Voltage Reference and
Battery Temperature ý AT90S2333 Battery
Charger ý ATtiny15 Battery Charger
ý Charge Current ý Software
Implementation ý User Settings ý Source
Code ý INT Battery Function ý The
Stable_ADC Function ý BC.H ý B_DEF.H
ý Charge MethodýSLA.C ý Charge
MethodýNiCd.C and NiMH.C ý Charge MethodýLilon.C
ý Suggested Improvement ý Sources
and PDF
THE STABLE_ADC FUNCTION
The stable_ADC function is used
when measuring battery voltage or temperature (see Figure 7). It makes
sure the ADC values are stable inside a defined area. This is important
for an accurate measurement. The function loops until it gets three
ADC values where the highest is no more than one step higher than
the lowest.
 |
| Figure 7ýHere the ADC accuracy
is increasing. |
PREVIOUS
NEXT
Circuit Cellar provides up-to-date information for engineers. Visit
www.circuitcellar.com for
more information and additional articles.
For subscription information, call (860) 875-2199, subscribe@circuitcellar.com
or subscribe online.
ýCircuit Cellar, the Magazine for Computer Applications. Posted with
permission. |